10KVA/1PH MAHINDRA MAKE 2012/500HRS Specification

  • Bore *Stroke
  • 100mm x 120mm
  • Pressure
  • Compression Ratio 17.5:1
  • Alternator
  • Brushless, Self-excited
  • Insulation
  • Class H
  • Poles Number
  • 4
  • Engine Type
  • 4 Stroke, Direct Injection, Diesel
  • Fuel Consumption
  • 2-2.5 ltrs/hr (at full load)
  • Standard
  • ISO 9001/BS 5000
  • Engine Model
  • Mahindra Powerol
  • Fuel Tank Capacity
  • 40 Litres
  • Dimension (L*W*H)
  • 2000 x 1000 x 1200 mm (approx.)
  • Protection Class
  • IP23
  • Product Type
  • Diesel Generator
  • Output Type
  • Single Phase AC
  • Rated Power
  • 10 KVA
  • Rated Voltage
  • 230 V
  • Starting Type
  • Electric Start
  • Rated Frequency
  • 50 Hz
  • Power Range
  • 10 KVA
  • Color
  • Green
  • Cooling System
  • Water Cooled
  • Noise Level
  • Silent / Sound Proof
  • Phase
  • Single Phase
  • Speed
  • 1500 RPM
  • Weight
  • Approx. 500 Kg
  • Year of Manufacture
  • 2012
  • Emission Norms
  • Meets CPCB norms
  • Control Panel
  • Standard with ammeters, voltmeter, and digital hour meter
  • Running Hours
  • 500 Hrs only
  • Frequency Regulation
  • ±1%
  • Mobility
  • Base-Mounted
  • Material
  • Heavy Duty Steel Enclosure
  • Application
  • Industrial / Commercial Backup Power
  • Duty Cycle
  • Continuous (Prime Power)
  • Exhaust System
  • Low Emission, Side Exhaust
  • Automatic Voltage Regulator
  • Yes, Integrated AVR
  • Lubrication System
  • Forced Lubrication
  • Fuel Type
  • High Speed Diesel
 

10KVA/1PH MAHINDRA MAKE 2012/500HRS Trade Information

  • Minimum Order Quantity
  • 1 Number
  • Sample Available
  • No
  • Main Domestic Market
  • [, ', A, l, l, , I, d, i, a, ', ], n
 

About 10KVA/1PH MAHINDRA MAKE 2012/500HRS


Alternator
  • STAMFORD
Engine
  • Mahindra Mechanical Engine, In-Line 4 stroke, radiator cooled engine.
  • Low fuel consumption with Inline fuel pump.
  • Dry type air cleaner with service indicator.
  • First fill of lube oil & coolant.
  • Electrical starter motor with soft start system.
  • Battery charging alternator.
Controller
  • AMF, manual and remote start/stop modes for 1-ph.



Reliable Power for Demanding Environments

The 10KVA/1PH Mahindra generator is built for high-duty industrial and commercial sectors. With a continuous prime duty cycle and integrated automatic voltage regulation, it ensures consistent power delivery even during extended outages, providing peace of mind and operational continuity.


Efficient Engine and Low Operating Costs

Powered by a Mahindra Powerol engine, this generator features a forced lubrication system, direct injection, and fuel efficiency of just 2-2.5 liters per hour at full load. Its 40-liter tank supports long hours of uninterrupted operation while minimizing fuel costs and maintenance demands.


Quiet and Safe Operation

Enclosed in a heavy-duty, soundproof steel body and equipped with a side exhaust system, this generator provides low-emission, silent operation. With compliance to CPCB emission standards and protection class IP23, it ensures safety, environmental responsibility, and minimal disruption.

FAQ's of 10KVA/1PH MAHINDRA MAKE 2012/500HRS:


Q: How does the integrated Automatic Voltage Regulator (AVR) improve generator performance?

A: The integrated AVR maintains a stable output voltage within 1%, protecting sensitive equipment from voltage fluctuations and ensuring smooth, reliable power delivery for your industrial or commercial needs.

Q: What is the process for starting and operating the 10KVA Mahindra generator?

A: Starting the generator is simple with the electric start function. Once started, the digital control panel allows easy monitoring of parameters like current, voltage, and runtime, ensuring safe and user-friendly operation.

Q: When should scheduled maintenance be performed on this generator?

A: Regular maintenance, such as oil and filter changes, should be performed according to the manufacturer's schedule or after every 250-500 operating hours. Given the current usage of 500 hours, a thorough check-up is recommended before extended use.

Q: Where can this generator be installed and used?

A: Designed with a base-mounted configuration and compact dimensions (2000 x 1000 x 1200 mm), this generator is suited for both indoor and outdoor industrial or commercial settings in India. Ensure proper ventilation and compliance with safety norms during installation.

Q: What are the primary benefits of choosing this Mahindra generator as a backup power source?

A: Key advantages include robust construction, low fuel consumption, soundproof and low-emission operation, as well as continuous (prime) duty capability, making it an ideal solution for uninterrupted industrial or commercial power supply during outages.

Q: How does the cooling and exhaust system contribute to longevity and performance?

A: The water-cooled engine, combined with a low-emission side exhaust system, minimizes heat build-up and reduces environmental impact, ensuring reliable performance and extending engine life under continuous operation.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Used Diesel Generator Category

Industrial Used Diesel Generator

Industrial Used Diesel Generator

Price 1,00,000 INR / Piece

Minimum Order Quantity : 50 Pieces

Voltage : 220 Volt (v)

Machine Type : Diesel Generator

Warranty : Yes

Used For : Industrial

Used Diesel Generator Set

Used Diesel Generator Set

Price 500000 INR / Piece

Minimum Order Quantity : 50 Pieces

Voltage : 220 Volt (v)

Machine Type : Diesel Generator Set

Warranty : Yes

Used For : Industrial



Back to top